stent ib1416 120 120 Search Results


86
Lifetech Scientific Corporation bridging overlay stents
Bridging Overlay Stents, supplied by Lifetech Scientific Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/stent+ib1416+120+120/bridging+overlay+stents/pm41854571-44-6-11
Average 86 stars, based on 1 article reviews
bridging overlay stents - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Lifetech Scientific Corporation bsgs
Placement of the First Bifurcation Stent Graft System (BSGS) (IB1410-080-130)
Bsgs, supplied by Lifetech Scientific Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/stent+ib1416+120+120/bsgs/pmc12882673-21-2-4
Average 86 stars, based on 1 article reviews
bsgs - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Lifetech Scientific Corporation stent ib1416 120 120
Placement of the First Bifurcation Stent Graft System (BSGS) (IB1410-080-130)
Stent Ib1416 120 120, supplied by Lifetech Scientific Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/stent+ib1416+120+120/connecting+the/pmc12882673-20-10-8
Average 86 stars, based on 1 article reviews
stent ib1416 120 120 - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

Image Search Results


Placement of the First Bifurcation Stent Graft System (BSGS) (IB1410-080-130)

Journal: JACC Case Reports

Article Title: First-Time Use of a Novel Off-the-Shelf Device for Treating Juxtarenal/Pararenal Hourglass Abdominal Aortic Aneurysms

doi: 10.1016/j.jaccas.2025.106596

Figure Lengend Snippet: Placement of the First Bifurcation Stent Graft System (BSGS) (IB1410-080-130)

Article Snippet: The final BSGS (IB1414-60-120, Lifetech Scientific) was introduced, bridging the overlying stent and reconstructing the left common iliac artery through the BSGS side branch (PS-C-10080-XL, Lifetech Scientific) ( ) ( and ).

Techniques:

Reconstruction of the Left Renal Artery Through the BSGS Main Body Reconstruction of the Left Renal Artery (PS-C-120-60-XL, PS-C-070-80-XL)

Journal: JACC Case Reports

Article Title: First-Time Use of a Novel Off-the-Shelf Device for Treating Juxtarenal/Pararenal Hourglass Abdominal Aortic Aneurysms

doi: 10.1016/j.jaccas.2025.106596

Figure Lengend Snippet: Reconstruction of the Left Renal Artery Through the BSGS Main Body Reconstruction of the Left Renal Artery (PS-C-120-60-XL, PS-C-070-80-XL)

Article Snippet: The final BSGS (IB1414-60-120, Lifetech Scientific) was introduced, bridging the overlying stent and reconstructing the left common iliac artery through the BSGS side branch (PS-C-10080-XL, Lifetech Scientific) ( ) ( and ).

Techniques:

Reconstruction of the Left Renal Artery Through the BSGS Main Body Reconstruction of the Left Renal Artery (PS-C-120-60-XL, PS-C-070-80-XL)

Journal: JACC Case Reports

Article Title: First-Time Use of a Novel Off-the-Shelf Device for Treating Juxtarenal/Pararenal Hourglass Abdominal Aortic Aneurysms

doi: 10.1016/j.jaccas.2025.106596

Figure Lengend Snippet: Reconstruction of the Left Renal Artery Through the BSGS Main Body Reconstruction of the Left Renal Artery (PS-C-120-60-XL, PS-C-070-80-XL)

Article Snippet: The final BSGS (IB1414-60-120, Lifetech Scientific) was introduced, bridging the overlying stent and reconstructing the left common iliac artery through the BSGS side branch (PS-C-10080-XL, Lifetech Scientific) ( ) ( and ).

Techniques:

A Second BSGS (IB1414-060-130) Was Introduced to Bridge the Long Leg of the Main Stent

Journal: JACC Case Reports

Article Title: First-Time Use of a Novel Off-the-Shelf Device for Treating Juxtarenal/Pararenal Hourglass Abdominal Aortic Aneurysms

doi: 10.1016/j.jaccas.2025.106596

Figure Lengend Snippet: A Second BSGS (IB1414-060-130) Was Introduced to Bridge the Long Leg of the Main Stent

Article Snippet: The final BSGS (IB1414-60-120, Lifetech Scientific) was introduced, bridging the overlying stent and reconstructing the left common iliac artery through the BSGS side branch (PS-C-10080-XL, Lifetech Scientific) ( ) ( and ).

Techniques:

The Final BSGS (IB1414-60-120) Was Introduced, Bridging the Overlying Stent and Reconstructing the Left Common Iliac Artery (PS-C-10080-XL)

Journal: JACC Case Reports

Article Title: First-Time Use of a Novel Off-the-Shelf Device for Treating Juxtarenal/Pararenal Hourglass Abdominal Aortic Aneurysms

doi: 10.1016/j.jaccas.2025.106596

Figure Lengend Snippet: The Final BSGS (IB1414-60-120) Was Introduced, Bridging the Overlying Stent and Reconstructing the Left Common Iliac Artery (PS-C-10080-XL)

Article Snippet: The final BSGS (IB1414-60-120, Lifetech Scientific) was introduced, bridging the overlying stent and reconstructing the left common iliac artery through the BSGS side branch (PS-C-10080-XL, Lifetech Scientific) ( ) ( and ).

Techniques:

The Final BSGS (IB1414-60-120) Was Introduced, Bridging the Overlying Stent and Reconstructing the Left Common Iliac Artery (PS-C-10080-XL)

Journal: JACC Case Reports

Article Title: First-Time Use of a Novel Off-the-Shelf Device for Treating Juxtarenal/Pararenal Hourglass Abdominal Aortic Aneurysms

doi: 10.1016/j.jaccas.2025.106596

Figure Lengend Snippet: The Final BSGS (IB1414-60-120) Was Introduced, Bridging the Overlying Stent and Reconstructing the Left Common Iliac Artery (PS-C-10080-XL)

Article Snippet: The final BSGS (IB1414-60-120, Lifetech Scientific) was introduced, bridging the overlying stent and reconstructing the left common iliac artery through the BSGS side branch (PS-C-10080-XL, Lifetech Scientific) ( ) ( and ).

Techniques:

Preoperative, Intraoperative, and Postoperative Imaging (A) Preoperative CT scan revealing a type III thoracoabdominal aortic aneurysm. (B) Embolization of the celiac trunk artery and placement of the abdominal aortic coated stent (XJZDZ26120). (C) Placement of the first BSGS (IB1410-080-130) bridging the short leg of the main stent (red arrows point in the direction of the stent's side branches). (D) Reconstruction of the superior mesenteric artery through the side branches of the BSGS (PS-C-120-80-XL). (E) Reconstruction of the left renal artery through the BSGS main body reconstruction of the left renal artery (PS-C-120-60-XL, PS-C-070-80-XL). (F) Placement of a second BSGS (IB1414-060-130) bridging the long leg of the main stent. (G) Reconstruction of the right renal artery through the BSGS side branch (PS-C-070-50-XL). (H) Placement of a third BSGS (IB1414-60-120) bridging the overlay stent. (I) Reconstruction of the left common iliac artery through the BSGS side branch (PS-C-10080-XL). (J) Postoperative imaging. (K) Postoperative CT scan indicating the absence of endoleak or stent occlusion during the 3-month follow-up. BSGS = bifurcated stent graft system; CT = computed tomography.

Journal: JACC Case Reports

Article Title: First-Time Use of a Novel Off-the-Shelf Device for Treating Juxtarenal/Pararenal Hourglass Abdominal Aortic Aneurysms

doi: 10.1016/j.jaccas.2025.106596

Figure Lengend Snippet: Preoperative, Intraoperative, and Postoperative Imaging (A) Preoperative CT scan revealing a type III thoracoabdominal aortic aneurysm. (B) Embolization of the celiac trunk artery and placement of the abdominal aortic coated stent (XJZDZ26120). (C) Placement of the first BSGS (IB1410-080-130) bridging the short leg of the main stent (red arrows point in the direction of the stent's side branches). (D) Reconstruction of the superior mesenteric artery through the side branches of the BSGS (PS-C-120-80-XL). (E) Reconstruction of the left renal artery through the BSGS main body reconstruction of the left renal artery (PS-C-120-60-XL, PS-C-070-80-XL). (F) Placement of a second BSGS (IB1414-060-130) bridging the long leg of the main stent. (G) Reconstruction of the right renal artery through the BSGS side branch (PS-C-070-50-XL). (H) Placement of a third BSGS (IB1414-60-120) bridging the overlay stent. (I) Reconstruction of the left common iliac artery through the BSGS side branch (PS-C-10080-XL). (J) Postoperative imaging. (K) Postoperative CT scan indicating the absence of endoleak or stent occlusion during the 3-month follow-up. BSGS = bifurcated stent graft system; CT = computed tomography.

Article Snippet: The final BSGS (IB1414-60-120, Lifetech Scientific) was introduced, bridging the overlying stent and reconstructing the left common iliac artery through the BSGS side branch (PS-C-10080-XL, Lifetech Scientific) ( ) ( and ).

Techniques: Imaging, Computed Tomography